. .
Deutsch
Deutschland
Suchtools
Anmelden

Anmelden mit Facebook:

Registrieren
Passwort vergessen?


Such-Historie
Merkliste
Links zu eurobuch.com

Dieses Buch teilen auf…
..?
Buchtipps
Aktuelles
Tipp von eurobuch.com
FILTER
- 0 Ergebnisse
Kleinster Preis: 21.22 EUR, größter Preis: 26.95 EUR, Mittelwert: 23.71 EUR
Blasting Supplies - Various
Vergriffenes Buch, derzeit bei uns nicht verfügbar.
(*)
Various:

Blasting Supplies - Taschenbuch

2007, ISBN: 1406723576, Lieferbar binnen 4-6 Wochen Versandkosten:Versandkostenfrei innerhalb der BRD

ID: 9781406723571

Internationaler Buchtitel. In englischer Sprache. Verlag: ROUTLEDGE CHAPMAN & HALL, 144 Seiten, L=216mm, B=140mm, H=9mm, Gew.=191gr, [GR: 26800 - TB/Technik], [SW: - Technology & Industrial Arts], Kartoniert/Broschiert, Klappentext: BLASTING MACHINES ELECTRIC FUZES ELECTRIC SQUIBS LEADING WIRE CONNECTING WIRE GALVANOMETERS LEADING WIRE REELS THAWING KETTLES RHEOSTATS SAFETY FUSE BLASTING CAPS BLASTING MATS CAP CRIMPERS TAMPING BAGS E.I.DUPONTDENEMOUR5 POWDER COMPANY WILMINGTON, DELAWAREU5.A. PRESS OF DANDO COMPANY PHILADELPHIA Copyright, 1911 E. I. du Pont de Nemours Powder Co. Wilmington, Del. Foreword LTHOUGH the explosive itself very naturally demands first consideration when blasting is to be done, the fact must not be overlooked that it cannot be properly exploded without certain materials and appliances especially designed for the purpose, and which are commonly known as Blasting Supplies. In addition to those articles necessary to develop the energy of a charge of explosives, there are other devices which, although they may not be absolutely requisite, contribute to safety, certainty and economy in the use of explosives, and these are also included in the category of Blasting Supplies. The importance of keeping Blasting Supplies up to the highest standard in every respect cannot be over- estimated, for the very best grade costs but a trifle in comparison with the charge of explosives with which they are used. It is poor economy to attempt to deto- nate explosives with an inferior article, for this always results in a considerable waste of the value of the explos- ives. More than a hundred years experience in the manufacture, sale and use of all kinds of explosives has taught us that the popularity of our products depends entirely on the results which consumers have with them. With this in view, we must, from a standpoint of good business, if from no other, recommend only a high quality of Blasting Supplies.251752 INDEX ADVANTAGES OF STRONG DETONATORS - 85 BLASTING BY ELECTRICITY - - - . . 5 BLASTING CAPS - - . - . - - 63 BLASTING MACHINES - . - . 29 BLASTING MATS - ... - - 82 BLASTING SUPPLIES AND THEIR USE - ... 1 CAP CRIMPERS - . . . - . . CONNECTING WIRE ... . . . -77 39 DELAY ELECTRIC FUZES - - - - -17 ELECTRIC FUZES - . . . 11 ELECTRIC SQUIBS - - - - - -23 ELEMENTARY PRINCIPLES OF ELECTRICITY - - - 91 GALVANOMETERS -.-.... 43 INTRODUCTION ..., .... LEADING WIRE... .... 39 LEADING WIRE REEL - - 40 PRECAUTIONS TO BE OBSERVED WITH EXPLOSIVES - -114 RHEOSTATS - 55 SAFETY FUSE - . - . .... 67 TAMPING BAGS - - . - - 81 THAWING KETTLES 78 INTRODUCTION Blasting Supplies and Their Use LECTRIC Fuzes are the detonators used when a high explosive, such as dynamite, is fired electric- ally. They consist of a copper capsule, or shell, containing a detonating charge surrounding a fine platinum bridge, which joins the tips of two insulated copper wires of various lengths. The ends of the copper wires are secured in the copper shell by a composition plug, which also serves to keep moisture and water away from the charge. The Electric Fuzes . electric fuze is detonated when sufficient current is passed through the 5 copper wires, and across the ill platinum bridge, to heat the latter to a temperature high enough to ignite the charge surrounding it. Delay Delay Electric Fuzes can be used to advantage in certain classes of tunnel or shaft excavating. These Electric Fuzes . are made so that a very short space of time intervenes between their ignition by the electric current and their detonation. By their use, it is possible, with but one opera- tion of the blasting machine, to fire one section of a blast, sufficiently ahead of the following section, for the material in the first to be out of the way when the next is blasted. When several charges of explosives are to be detonated at one time with electric fuzes, it is neces- sary unless the electric fuze wires are long enough to reach between the bore holes to join them with Connecting Wire. Insulated copper wire is used for this purpose... BLASTING MACHINES ELECTRIC FUZES ELECTRIC SQUIBS LEADING WIRE CONNECTING WIRE GALVANOMETERS LEADING WIRE REELS THAWING KETTLES RHEOSTATS SAFETY FUSE BLASTING CAPS BLASTING MATS CAP CRIMPERS TAMPING BAGS E.I.DUPONTDENEMOUR5 POWDER COMPANY WILMINGTON, DELAWAREU5.A. PRESS OF DANDO COMPANY PHILADELPHIA Copyright, 1911 E. I. du Pont de Nemours Powder Co. Wilmington, Del. Foreword LTHOUGH the explosive itself very naturally demands first consideration when blasting is to be done, the fact must not be overlooked that it cannot be properly exploded without certain materials and appliances especially designed for the purpose, and which are commonly known as Blasting Supplies. In addition to those articles necessary to develop the energy of a charge of explosives, there are other devices which, although they may not be absolutely requisite, contribute to safety, certainty and economy in the use of explosives, and these are also included in the category of Blasting Supplies. The importance of keeping Blasting Supplies up to the highest standard in every respect cannot be over- estimated, for the very best grade costs but a trifle in comparison with the charge of explosives with which they are used. It is poor economy to attempt to deto- nate explosives with an inferior article, for this always results in a considerable waste of the value of the explos- ives. More than a hundred years experience in the manufacture, sale and use of all kinds of explosives has taught us that the popularity of our products depends entirely on the results which consumers have with them. With this in view, we must, from a standpoint of good business, if from no other, recommend only a high quality of Blasting Supplies.251752 INDEX ADVANTAGES OF STRONG DETONATORS - 85 BLASTING BY ELECTRICITY - - - . . 5 BLASTING CAPS - - . - . - - 63 BLASTING MACHINES - . - . 29 BLASTING MATS - ... - - 82 BLASTING SUPPLIES AND THEIR USE - ... 1 CAP CRIMPERS - . . . - . . CONNECTING WIRE ... . . . -77 39 DELAY ELECTRIC FUZES - - - - -17 ELECTRIC FUZES - . . . 11 ELECTRIC SQUIBS - - - - - -23 ELEMENTARY PRINCIPLES OF ELECTRICITY - - - 91 GALVANOMETERS -.-.... 43 INTRODUCTION ..., .... LEADING WIRE... .... 39 LEADING WIRE REEL - - 40 PRECAUTIONS TO BE OBSERVED WITH EXPLOSIVES - -114 RHEOSTATS - 55 SAFETY FUSE - . - . .... 67 TAMPING BAGS - - . - - 81 THAWING KETTLES 78 INTRODUCTION Blasting Supplies and Their Use LECTRIC Fuzes are the detonators used when a high explosive, such as dynamite, is fired electric- ally. They consist of a copper capsule, or shell, containing a detonating charge surrounding a fine platinum bridge, which joins the tips of two insulated copper wires of various lengths. The ends of the copper wires are secured in the copper shell by a composition plug, which also serves to keep moisture and water away from the charge. The Electric Fuzes . electric fuze is detonated when sufficient current is passed through the 5 copper wires, and across the ill platinum bridge, to heat the latter to a temperature high enough to ignite the charge surrounding it. Delay Delay Electric Fuzes can be used to advantage in certain classes of tunnel or shaft excavating. These Electric Fuzes . are made so that a very short space of time intervenes between their ignition by the electric current and their detonation. By their use, it is possible, with but one opera- tion of the blasting machine, to fire one section of a blast, sufficiently ahead of the following section, for the material in the first to be out of the way when the next is blasted. When several charges of explosives are to be detonated at one time with electric fuzes, it is neces- sary unless the electric fuze wires are long enough to reach between the bore holes to join them with Connecting Wire. Insulated copper wire is used for this purpose...

Neues Buch DEU
Buchgeier.com
Lieferbar binnen 4-6 Wochen (Besorgungstitel) Versandkosten:Versandkostenfrei innerhalb der BRD
Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.
Blasting Supplies - Various
Vergriffenes Buch, derzeit bei uns nicht verfügbar.
(*)

Various:

Blasting Supplies - signiertes Exemplar

2007, ISBN: 1406723576, Lieferbar binnen 4-6 Wochen

Taschenbuch, ID: 9781406723571

Internationaler Buchtitel. In englischer Sprache. Verlag: ROUTLEDGE CHAPMAN & HALL, 144 Seiten, L=216mm, B=140mm, H=9mm, Gew.=191gr, [GR: 26800 - TB/Technik], [SW: - Technology & Industrial Arts], Kartoniert/Broschiert, Klappentext: BLASTING MACHINES ELECTRIC FUZES ELECTRIC SQUIBS LEADING WIRE CONNECTING WIRE GALVANOMETERS LEADING WIRE REELS THAWING KETTLES RHEOSTATS SAFETY FUSE BLASTING CAPS BLASTING MATS CAP CRIMPERS TAMPING BAGS E.I.DUPONTDENEMOUR5 POWDER COMPANY WILMINGTON, DELAWAREU5.A. PRESS OF DANDO COMPANY PHILADELPHIA Copyright, 1911 E. I. du Pont de Nemours Powder Co. Wilmington, Del. Foreword LTHOUGH the explosive itself very naturally demands first consideration when blasting is to be done, the fact must not be overlooked that it cannot be properly exploded without certain materials and appliances especially designed for the purpose, and which are commonly known as Blasting Supplies. In addition to those articles necessary to develop the energy of a charge of explosives, there are other devices which, although they may not be absolutely requisite, contribute to safety, certainty and economy in the use of explosives, and these are also included in the category of Blasting Supplies. The importance of keeping Blasting Supplies up to the highest standard in every respect cannot be over- estimated, for the very best grade costs but a trifle in comparison with the charge of explosives with which they are used. It is poor economy to attempt to deto- nate explosives with an inferior article, for this always results in a considerable waste of the value of the explos- ives. More than a hundred years experience in the manufacture, sale and use of all kinds of explosives has taught us that the popularity of our products depends entirely on the results which consumers have with them. With this in view, we must, from a standpoint of good business, if from no other, recommend only a high quality of Blasting Supplies.251752 INDEX ADVANTAGES OF STRONG DETONATORS - 85 BLASTING BY ELECTRICITY - - - . . 5 BLASTING CAPS - - . - . - - 63 BLASTING MACHINES - . - . 29 BLASTING MATS - ... - - 82 BLASTING SUPPLIES AND THEIR USE - ... 1 CAP CRIMPERS - . . . - . . CONNECTING WIRE ... . . . -77 39 DELAY ELECTRIC FUZES - - - - -17 ELECTRIC FUZES - . . . 11 ELECTRIC SQUIBS - - - - - -23 ELEMENTARY PRINCIPLES OF ELECTRICITY - - - 91 GALVANOMETERS -.-.... 43 INTRODUCTION ..., .... LEADING WIRE... .... 39 LEADING WIRE REEL - - 40 PRECAUTIONS TO BE OBSERVED WITH EXPLOSIVES - -114 RHEOSTATS - 55 SAFETY FUSE - . - . .... 67 TAMPING BAGS - - . - - 81 THAWING KETTLES 78 INTRODUCTION Blasting Supplies and Their Use LECTRIC Fuzes are the detonators used when a high explosive, such as dynamite, is fired electric- ally. They consist of a copper capsule, or shell, containing a detonating charge surrounding a fine platinum bridge, which joins the tips of two insulated copper wires of various lengths. The ends of the copper wires are secured in the copper shell by a composition plug, which also serves to keep moisture and water away from the charge. The Electric Fuzes . electric fuze is detonated when sufficient current is passed through the 5 copper wires, and across the ill platinum bridge, to heat the latter to a temperature high enough to ignite the charge surrounding it. Delay Delay Electric Fuzes can be used to advantage in certain classes of tunnel or shaft excavating. These Electric Fuzes . are made so that a very short space of time intervenes between their ignition by the electric current and their detonation. By their use, it is possible, with but one opera- tion of the blasting machine, to fire one section of a blast, sufficiently ahead of the following section, for the material in the first to be out of the way when the next is blasted. When several charges of explosives are to be detonated at one time with electric fuzes, it is neces- sary unless the electric fuze wires are long enough to reach between the bore holes to join them with Connecting Wire. Insulated copper wire is used for this purpose...

Neues Buch eurobuch.neubuch
Buchgeier.com
Lieferbar binnen 4-6 Wochen (Besorgungstitel)
Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.
Blasting Supplies - Various
Vergriffenes Buch, derzeit bei uns nicht verfügbar.
(*)
Various:
Blasting Supplies - Taschenbuch

1911

ISBN: 9781406723571

[ED: Taschenbuch], [PU: ROUTLEDGE CHAPMAN & HALL], BLASTING MACHINES ELECTRIC FUZES ELECTRIC SQUIBS LEADING WIRE CONNECTING WIRE GALVANOMETERS LEADING WIRE REELS THAWING KETTLES RHEOSTATS SAFETY FUSE BLASTING CAPS BLASTING MATS CAP CRIMPERS TAMPING BAGS E.I.DUPONTDENEMOUR5 POWDER COMPANY WILMINGTON, DELAWAREU5.A. PRESS OF DANDO COMPANY PHILADELPHIA Copyright, 1911 E. I. du Pont de Nemours Powder Co. Wilmington, Del. Foreword LTHOUGH the explosive itself very naturally demands first consideration when blasting is to be done, the fact must not be overlooked that it cannot be properly exploded without certain materials and appliances especially designed for the purpose, and which are commonly known as Blasting Supplies. In addition to those articles necessary to develop the energy of a charge of explosives, there are other devices which, although they may not be absolutely requisite, contribute to safety, certainty and economy in the use of explosives, and these are also included in the category of Blasting Supplies. The importance of keeping Blasting Supplies up to the highest standard in every respect cannot be over- estimated, for the very best grade costs but a trifle in comparison with the charge of explosives with which they are used. It is poor economy to attempt to deto- nate explosives with an inferior article, for this always results in a considerable waste of the value of the explos- ives. More than a hundred years experience in the manufacture, sale and use of all kinds of explosives has taught us that the popularity of our products depends entirely on the results which consumers have with them. With this in view, we must, from a standpoint of good business, if from no other, recommend only a high quality of Blasting Supplies.251752 INDEX ADVANTAGES OF STRONG DETONATORS - 85 BLASTING BY ELECTRICITY - - - . . 5 BLASTING CAPS - - . - . - - 63 BLASTING MACHINES - . - . 29 BLASTING MATS - ... - - 82 BLASTING SUPPLIES AND THEIR USE - ... 1 CAP CRIMPERS - . . . - . . CONNECTING WIRE ... . . . -77 39 DELAY ELECTRIC FUZES - - - - -17 ELECTRIC FUZES - . . . 11 ELECTRIC SQUIBS - - - - - -23 ELEMENTARY PRINCIPLES OF ELECTRICITY - - - 91 GALVANOMETERS -.-.... 43 INTRODUCTION ..., .... LEADING WIRE... .... 39 LEADING WIRE REEL - - 40 PRECAUTIONS TO BE OBSERVED WITH EXPLOSIVES - -114 RHEOSTATS - 55 SAFETY FUSE - . - . .... 67 TAMPING BAGS - - . - - 81 THAWING KETTLES 78 INTRODUCTION Blasting Supplies and Their Use LECTRIC Fuzes are the detonators used when a high explosive, such as dynamite, is fired electric- ally. They consist of a copper capsule, or shell, containing a detonating charge surrounding a fine platinum bridge, which joins the tips of two insulated copper wires of various lengths. The ends of the copper wires are secured in the copper shell by a composition plug, which also serves to keep moisture and water away from the charge. The Electric Fuzes . electric fuze is detonated when sufficient current is passed through the 5 copper wires, and across the ill platinum bridge, to heat the latter to a temperature high enough to ignite the charge surrounding it. Delay Delay Electric Fuzes can be used to advantage in certain classes of tunnel or shaft excavating. These Electric Fuzes . are made so that a very short space of time intervenes between their ignition by the electric current and their detonation. By their use, it is possible, with but one opera- tion of the blasting machine, to fire one section of a blast, sufficiently ahead of the following section, for the material in the first to be out of the way when the next is blasted. When several charges of explosives are to be detonated at one time with electric fuzes, it is neces- sary unless the electric fuze wires are long enough to reach between the bore holes to join them with Connecting Wire. Insulated copper wire is used for this purpose... Versandfertig in über 4 Wochen, [SC: 0.00]

Neues Buch Booklooker.de
buecher.de GmbH & Co. KG
Versandkosten:Versandkostenfrei, Versand nach Deutschland (EUR 0.00)
Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.

< zum Suchergebnis...
Details zum Buch
Autor:

Various

Titel:

Blasting Supplies

ISBN-Nummer:

1406723576

BLASTING MACHINES ELECTRIC FUZES ELECTRIC SQUIBS LEADING WIRE CONNECTING WIRE GALVANOMETERS LEADING WIRE REELS THAWING KETTLES RHEOSTATS SAFETY FUSE BLASTING CAPS BLASTING MATS CAP CRIMPERS TAMPING BAGS E.I.DUPONTDENEMOUR5 POWDER COMPANY WILMINGTON, DELAWAREU5.A. PRESS OF DANDO COMPANY PHILADELPHIA Copyright, 1911 E. I. du Pont de Nemours Powder Co. Wilmington, Del. Foreword LTHOUGH the explosive itself very naturally demands first consideration when blasting is to be done, the fact must not be overlooked that it cannot be properly exploded without certain materials and appliances especially designed for the purpose, and which are commonly known as Blasting Supplies. In addition to those articles necessary to develop the energy of a charge of explosives, there are other devices which, although they may not be absolutely requisite, contribute to safety, certainty and economy in the use of explosives, and these are also included in the category of Blasting Supplies. The importance of keeping Blasting Supplies up to the highest standard in every respect cannot be over- estimated, for the very best grade costs but a trifle in comparison with the charge of explosives with which they are used. It is poor economy to attempt to deto- nate explosives with an inferior article, for this always results in a considerable waste of the value of the explos- ives. More than a hundred years experience in the manufacture, sale and use of all kinds of explosives has taught us that the popularity of our products depends entirely on the results which consumers have with them. With this in view, we must, from a standpoint of good business, if from no other, recommend only a high quality of Blasting Supplies.251752 INDEX ADVANTAGES OF STRONG DETONATORS - 85 BLASTING BY ELECTRICITY - - - . . 5 BLASTING CAPS - - . - . - - 63 BLASTING MACHINES - . - . 29 BLASTING MATS - ... - - 82 BLASTING SUPPLIES AND THEIR USE - ... 1 CAP CRIMPERS - . . . - . . CONNECTING WIRE ... . . . -77 39 DELAY ELECTRIC FUZES - - - - -17 ELECTRIC FUZES - . . . 11 ELECTRIC SQUIBS - - - - - -23 ELEMENTARY PRINCIPLES OF ELECTRICITY - - - 91 GALVANOMETERS -.-.... 43 INTRODUCTION ..., .... LEADING WIRE... .... 39 LEADING WIRE REEL - - 40 PRECAUTIONS TO BE OBSERVED WITH EXPLOSIVES - -114 RHEOSTATS - 55 SAFETY FUSE - . - . .... 67 TAMPING BAGS - - . - - 81 THAWING KETTLES 78 INTRODUCTION Blasting Supplies and Their Use LECTRIC Fuzes are the detonators used when a high explosive, such as dynamite, is fired electric- ally. They consist of a copper capsule, or shell, containing a detonating charge surrounding a fine platinum bridge, which joins the tips of two insulated copper wires of various lengths. The ends of the copper wires are secured in the copper shell by a composition plug, which also serves to keep moisture and water away from the charge. The Electric Fuzes . electric fuze is detonated when sufficient current is passed through the 5 copper wires, and across the ill platinum bridge, to heat the latter to a temperature high enough to ignite the charge surrounding it. Delay Delay Electric Fuzes can be used to advantage in certain classes of tunnel or shaft excavating. These Electric Fuzes . are made so that a very short space of time intervenes between their ignition by the electric current and their detonation. By their use, it is possible, with but one opera- tion of the blasting machine, to fire one section of a blast, sufficiently ahead of the following section, for the material in the first to be out of the way when the next is blasted. When several charges of explosives are to be detonated at one time with electric fuzes, it is neces- sary unless the electric fuze wires are long enough to reach between the bore holes to join them with Connecting Wire. Insulated copper wire is used for this purpose...

Detailangaben zum Buch - Blasting Supplies


EAN (ISBN-13): 9781406723571
ISBN (ISBN-10): 1406723576
Taschenbuch
Erscheinungsjahr: 2007
Herausgeber: ROUTLEDGE CHAPMAN & HALL
144 Seiten
Gewicht: 0,191 kg
Sprache: eng/Englisch

Buch in der Datenbank seit 07.11.2007 11:32:58
Buch zuletzt gefunden am 07.11.2011 17:40:05
ISBN/EAN: 1406723576

ISBN - alternative Schreibweisen:
1-4067-2357-6, 978-1-4067-2357-1

< zum Suchergebnis...
< zum Archiv...
Benachbarte Bücher